Auto Switch & Mobile Auto

Leading Manufacturers, Exporters, Wholesaler and Retailer of Snr /as/ 9000A Auto Switch, Snr /as/ 9001 Auto Switch, SNR/AS/2001R/DG Auto Switch, SNR/AS/9005 Auto Switch, Snr/msu/PG Auto Switch and SNR/MSU/PG/4G Auto Switch from Sangli.

Business Type Manufacturer, Exporter, Supplier
Type Microcontroller
Application 3 Ph. 3 To 30 H.P. Openwell, Submersible, Monoblock Pumpsets
Operating Voltage- 220 to 460 Vac, 50 Hz.
Dry Run Trip Timing 7sec
Technology Microcontroller Based
Operating Voltage 220 To 460 VAC, 50 Hz
Origin India

Features:

  • Microcontroller based technology.

  • Motor starts automatically as supply is ON in 1/3/5 minutes.

  • Protection from unbalance voltage.

  • Protects the motor from single phasing.

  • Operates on low voltage (from 200 V)

  • Useful for 3 Ph. 3 to 7.5 H.P. (D.O.L Starter) Openwell, Submersible, Monoblock pumpsets.

  • Separate indications for Timer, OK & SPP.

  • In phase reversal condition SPP LED Blinks.

  • Auto Manual Facility.

  • SNR/AS/NANO – SMPS Power supply. Other Features same as per AS/9001

Technical Specifications:

  • Operating voltage – 220 to 460 VAC, 50Hz.

  • SPP Trip time delay – 4 sec.

  • Voltage Unbalance Setting – 35 volts phase to phase.

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Type Microcontroller
Application Industrial Applications
Material Silicon
Operating voltage- 220 to 460 VAC, 50Hz.
SPP Trip time delay sec.
Interface I2C, SPI, UART
Power Consumption Low Power Consumption
Voltage Unbalance Setting 35 volts phase to phase.
Storage Temperature -40 To 125°C
Origin India

Click to view more

Introducing the Snr/as/9001 Microcontroller, designed for industrial applications. Made from high-quality silicon, this microcontroller operates at a voltage range of 220 to 460 VAC. With a fast SPP trip time delay in seconds and an I2C interface, it offers low power consumption for efficient performance.

AUTOSWITCH (SNR/AS 9001)

Features:

 

  • Microcontroller based technology.

  • Motor starts automatically as supply is ON in 1/3/5 minutes.

  • Protection from unbalance voltage.

  • Protects the motor from single phasing.

  • Operates on low voltage (from 200 V)

  • Useful for 3 Ph. 3 to 30 H.P. Openwell, Submersible, Monoblock Pumpsets.

  • Separate indications for Timer, OK & SPP.

  • Auto / Manual Facility.

  • In phase reversal condition SPP LED Blinks.

 

Technical Specifications:

 

  • Operating voltage – 220 to 460 VAC, 50Hz.

  • SPP Trip time delay – 4 sec.

  • Voltage Unbalance Setting – 35 volts phase to phase.

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Type Microcontroller
Application 3 Ph. 1 To 7.5 H.P. (DOL Starter) Openwell, Submersible, Monoblock Pumpsets
Technology Microcontroller Based
Operating Voltage 220 To 460 VAC, 50 Hz
Dry Run Trip Timing 7 Sec
Dry Run Setting 70% Of Full Load Current
Origin India

DIGITAL AUTOSWITCH (SNR/AS RDM) (SNR/AS/2001R/DG)

Features:

  • Micro Controller Based Technology.

  • Motor starts automatically after on delay time (settable ondelay time)

  • LED display for all faults, current, voltage, protections.

  • After Dry Run trip restart time settable from 1 min. to 180 mins.

  • O/L. & D/R% settable.

  • SPP/O/L./protection enable/disable facility

  • Protection from voltage unbalance, Single Phasing & Dry Run (Automatic push button setting)

  • Useful for 3Ph., 3HP to 20HP openwell monoblock submersible pumps.

  • Overload current delay & dry run trip current shows in display.

  • Auto bypass facility.

  • Separate indicator for time, OK, SPP/O/L&D/R.

  • In phase reversal condition SPP LED Blinks.

  • Cyclic with enable & disable facility.

  • Timer with memory can be changed once.

Technical Specifications:

 

  • Operating voltage – 220 to 460 VAC

  • Dry Run trip timing – 7 Sec.

  • Overload trip time – 2 to 30 S (IDMT Dry run setting – 70% of full load current

  • Overload setting – 130% of full load.

  • Trip time delay – 4 sec.

  • Voltage Unbalance Setting – 35 volts phase to phase.

  • SPP Protection – current and voltage sensing.

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Type Microcontroller
Application Electrical Devices
Power Source Electric
Trip Time Delay 4 Sec
Star To Delta Time Delay 7 Sec
Technology Microcontroller Based
Motor Start Delay 1/3/5 Minutes
Voltage Protection Unbalance Voltage, Single Phasing
Operating Voltage 220 To 460 VAC
Voltage Unbalance Setting 35 Volts
Origin India

Click to view more

Features:

  • Microcontroller based technology.

  • Motor starts automatically as supply is ON in 1/3/5 minutes.

  • Protection from unbalance voltage.

  • Protects the motor from single phasing.

  • Operates on low voltage (from 200 V)

  • Useful for 3 Ph. 3 to 30 H.P. Openwell, Submersible, Monoblock Pumpsets.

  • Separate indications for Timer, OK & SPP.

  • Auto / Manual Facility.

  • In phase reversal condition SPP LED Blinks.

Technical Specifications:

 

  • As per AUTOSWITCH (SNR/AS 9001)

  • Star to Delta Time Delay - 7 Sec.

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Type Microcontroller
Power Source Electric
Model Number Snr/msu/pg
Usage Power Automation For Mobile Start Unit, Motor Operation, Protection From Voltage Issues
Features Microcontroller Based Technology.,Useful For 1 Ph. & 3 Ph. To 30 H.P.,Motor Can Be Operated By Mobile On Calling Or SMS From Any Destination Automatically.,Audio Feedback Or SMS Feedback Of Each Operation And Protection.,Mobile Auto Can Operate From Speci
Technical Specifications 220 To 460 VAC, 50 Hz,7 Sec,70% Of Full Load Current,4 Sec,7 Sec,35 Volts
Frequency 50 Hz
Condition New

Click to view more

POWER AUTOMATION PEOPLE

MOBILE START UNIT (SNR/MSU/PG)

 

Features:

  • Microcontroller based technology.
  • Useful for 1 Ph. & 3 Ph. to 30 H.P.
  • Motor can be operated by mobile on calling or SMS from any destination automatically. (Mobile Network necessary)
  • You will get Audio feedback or SMS feedback of each operation and protection.
  • Mobile Auto can Operate from Specific Numbers (4 Nos.) which will be feed by customer for his convenience to avoid misuse of Mobile Auto.
  • Protection from voltage unbalance, reverse phasing, single phasing, & Dryrun.
  • In phase reversal condition SPP LED Blinks.
  • Separate indicator for OK, SPP, N/L & Mobile ON
  • You can direct insert Simcard to this unit.
  • For details of voice feedback & other information please refer instruction manual with this unit.

Technical Specifications:

  • Operating voltage – 220 to 460 VAC, 50 Hz.
  • Dry run trip timing - 7 Sec.
  • Dry run setting – 70% of full load current
  • SPP Trip time delay - 4 sec.
  • Star to Delta Time Delay – 7 Sec.
  • Voltage Unbalance setting - 35 volts.

 

Read More...


Request to Call


Business Type Manufacturer, Exporter, Supplier
Country of Origin India
Type Microcontroller
Power Source Electric
Usage Mobile Start Unit For 1 Ph. & 3 Ph. Up To 30 H.P. Motors, With Mobile Operation Via Calling Or SMS, Protection From Various Electrical Issues, Digital Display For Voltage & Current.
Features Microcontroller Based Technology.,Motor Can Be Operated By Mobile On Calling Or SMS From Any Destination Automatically.,Audio Feedback Or SMS Feedback Of Each Operation And Protection.,Mobile Auto Can Operate From Specific Numbers (4 Nos.),Protection From
Model SNR/MSU/PG
Display Digital LCD
Frequency 50 Hz
Condition New

Click to view more

MOBILE START UNIT (SNR/MSU/PG/4G)\\n

Features:

  • Microcontroller based technology.
  • Useful for 1 Ph. & 3 Ph. to 30 H.P.
  • Motor can be operated by mobile on calling or SMS from any destination automatically. (Mobile Network necessary)
  • You will get Audio feedback or SMS feedback of each operation and protection.
  • Mobile Auto can Operate from Specific Numbers (4 Nos.) which will be feed by customer for his convenience to avoid misuse of Mobile Auto.
  • Protection from voltage unbalance, overload, High voltage, low voltage, reverse phasing, single phasing, & Dryrun.
  • Separate indicator for OK, SPP, N/L & Mobile ON
  • In phase reversal condition SPP LED Blinks.
  • You can direct insert Simcard to this unit.
  • For details of voice feedback & other information please refer instruction manual with this unit.
  • Digital display for voltage & current.
  • Over load Trip current & dry run Trip current shows on display with LED Indicator.

 

Technical Specifications:

  • As per Model - SNR/MSU/PG
  • Technical Specifications:
  • As per Model - SNR/MSU/PG

 

Read More...


Request to Call